Chapter 2 Installation and Setup Installation and Operation Manual
2-2 Setting the Internal Jumpers ASMi-52CD Ver. 1.0
2.2 Package Contents
The ASMi-52CD package includes the following items:
• ASMi-52CD modem card
• Matching interface module
• Technical documentation CD
• Interface cable for connecting an interface module to the appropriate DTE:
RS-530 – CBL-SCS26/530 (if ordered)
V.35 – CBL-SCS26/V35 (if ordered)
X.21 – CBL-SCS26/X21 (if ordered)
Unbalanced G.704 E1 – CBL-LRSI25/DB25/UB (if ordered).
2.3 Setting the Internal Jumpers
Figure 2-1
illustrates the basic ASMi-52CD module layout.
J7
J3
J6
GND-FGND
N Y
POWER
DATA
ALM
SYNC
TST
JP2
U8
SHDSL Board
DTE Board
DTE Board
WD
1
JP1
Figure 2-1. ASMi-52CD Jumpers
Check that the following jumpers have been set properly:
• The JP8 jumper cap is installed over pin 1.
• The JP10 jumper is set to Y.